HP500A-120KW-HD-D0

P/N Custom

High power detector for laser power measurement up to 120 000 W.

    • QBH
    • 60 mm Ø
    • 100 mm Ø
    • 250 mm Ø
    • 125 x 125 mm
    • 280 x 280 mm
    • 500 x 500 mm
    • HD - Broadband, high power
    • GD - High power density, large cone
    • GD - High power density, small cone
    • HE - Broadband, high power
    • Standard (without TUBE)
    • Low (with TUBE)
    • Metric
    • Imperial
    • Standard (DB15) + USB
    • BLU (DB15 + wireless)
HP500A-120KW-HD-D0 HP500A-120KW-HD-D0 HP500A-120KW-HD-D0 HP500A-120KW-HD-D0 HP500A-120KW-HD-D0 HP500A-120KW-HD-D0 HP500A-120KW-HD-D0 HP500A-120KW-HD-D0 HP500A-120KW-HD-D0 HP500A-120KW-HD-D0 HP500A-120KW-HD-D0 HP500A-120KW-HD-D0 HP500A-120KW-HD-D0 HP500A-120KW-HD-D0 HP500A-120KW-HD-D0 HP500A-120KW-HD-D0 HP500A-120KW-HD-D0 HP500A-120KW-HD-D0

Traceable calibration:

Logo nist

Product family key features

CUSTOM-BUILT

Contact us with your requirements for a version tailored to your needs

The Highest Power Handling

Custom models handle up to 120 000 W of continuous power. Higher powers are available upon request.

Stable Reading

Less sensitive to variations in water cooling temperature than any other high-power water-cooled meter on the market.

Infinite Customization Capabilities

  • Choose your size
  • Choose your maximum power
  • We will customize one just for you!

Compact and Light Weight

Lighter and more compact than any other high-power detector on the market, thanks to our unique design.

Available with YAG and CO2 Calibration

All HP models can be calibrated at YAG and CO2 wavelengths with a calibration uncertainty of +/- 5%.

Direct USB Connection to a PC

Each head comes with both a DB-15 connector (for use with a Gentec-EO monitor) and a USB2.0 output for direct connection to a PC. Other connectors are available upon request.

 

Compatible displays & PC interfaces

  • MAESTRO MAESTRO

    Touchscreen display device for power & energy measurement. Single-channel, multiple outputs (USB, Ethernet, analog).

  • TUNER TUNER

    Display device with tuning needle for power measurement. Single-channel.

  • UNO UNO

    Economical display device for power measurement. Single-channel.

Included

  • Calibration certificate

  • Transport case

  • Personal wavelength correctionTM Certificate

  • Protective cover for optical surfaces

Measurement capabilities

  • Maximum average power (continuous)

    150000 W
  • Minimum average power1

    6000 W
  • Noise equivalent power2

    300 W
  • Spectral range

    0.193 - 20 μm
  • Typical rise time

    60 s
  • Power calibration uncertainty

    ±5 %
  • Back reflections

    ~ 15 %
    • 1. For lower powers, call your Gentec-EO representative.
    • 2. Depending on cooling water flow and temperature stability

Water requirements

  • Required cooling flow1

    (36 - 48) LPM < ±1 LPM/min
  • Temperature range

    15 – 25 °C
  • Rate of temperature change

    < ±1°C/min
  • Maximum water pressure

    621 kPa (90 psi)
    • 1. Contact Gentec-EO for clean deionized water cooling module option.

Damage thresholds

  • Maximum average power density1

    3.5 kW/cm²
    • 1. At 1064 nm, 1.07-1.08 µm and 10.6 µm, 10 kW CW. Refer to user manual for damage threshold at other powers. May vary with wavelength and average power.

Controller and GUI specifications

  • Data display

    Real time, scope, needle, averaging, histogram and statistics
  • Analog output1

    0-2 Volts
  • Serial commands via

    USB
  • External power supply2

    Through USB or Gentec-EO displays & PC interfaces
  • Display type

    None
    • 1. 12 V maximum output signal available upon request.
    • 2. A USB power adaptor will be necessary if the HP is used with a DB-15 extension cable.

Physical characteristics

  • Cooling

    Water
  • Aperture width

    500 mm
  • Aperture height

    500 mm
  • Absorber

    HD
  • Dimensions

    525H x 525W x 90D mm

Broadband HD absorber: High performance for high-power lasers

Our HD absorber offers high damage thresholds and a flat broadband spectral response for high-power lasers in the kilowatt range. Detectors with this absorber are versatile and can cover several high-power measurement needs.

Customers enjoy:

  • Low risk of damaging the equipment thanks to high damage thresholds
  • Useful for measuring a wide range of high-power lasers

Use it with our included PC-Gentec-EO software

Read your measurements directly on your PC thanks to our free proprietary software PC-Gentec-EO. The software supports the following product series: P-LINK, HP, INTEGRA, U-LINK, and MAESTRO.

Enjoy:

  • Practical displays: real-time, scope, needle, averaging, histogram, and statistics
  • Useful features such as data logging and correction factors
  • Many statistics available: current value, average value, maximum value, minimum value, RMS stability, PTP stability, repetition rate, average power, and STD deviation

 

Learn more

Faster measurement with XNR AnticipationTM

Measure laser power up to 10x faster (model-dependant) with XNR AnticipationTM. Our proprietary algorithm looks at the rate at which the signal increases or decreases and combines this with calibration data to predict the result. The measurement is therefore calculated and displayed faster than the natural response of the detector.

Why does it matter?

  • Save several seconds to tens of seconds for each measurement
  • Shorter operation interruption
  • Faster laser output diagnostics
  • Increased productivity
  • No compromise on measurement accuracy

NIST-TRACEABLE CALIBRATION INCLUDED

Traceable calibration provides the ability to trace the readings of laser output measurements to known international measurement standards determined by the National Institute of Standards and Technology (NIST). This ensures that the measurements taken by the instruments are reliable and accurate.

Benefits include:

  • Make valid comparisons of measurements taken by other instruments inside and outside your organization and over time
  • Comply with regulations or conform to industry standards
  • Avoid costly measurement mistakes in your operations
  • Improve customer confidence in your laser systems
  • Ensure laboratory experiment validity
  • Demonstrate measurement accuracy easily with the calibration certificate we provide
 

Related videos

All videos

Compatible products you may need

Your item has been added to your cart!

You might need these specific products to be able to use the placeholder only.

Compatible products

No compatible product

Check if this product works for your laser

Measurement type:

1

Beam size

2

Laser type

3

Beam profile

COPYRIGHT ©2024 Gentec-eo Spektrum média