Laser power measurement

The largest selection of calibrated laser power sensors for measurement from 0.3 nW up to 100,000 W.

Solution type

  • All-in-one

    Portable solutions with integrated display.

  • Gentec-EO Display

    Connect to a table-top display device.

  • Pc-Based

    Connect to a PC with INTEGRA or a LINK solution.

  • Wireless

    Connect to a mobile, tablet or PC with BLU.

    QE12LP-S-MB-D0

    Aperture: 12 x 12 mm
    Max. energy: 0.85 J
    Absorber: MB - Standard
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE12LP-S-MB-QED-D0

    Aperture: 9 x 9 mm
    Max. energy: 3.9 J
    Absorber: MB - Standard
    Attenuator: QED

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE12LP-H-MB-D0

    Aperture: 12 x 12 mm
    Max. energy: 0.85 J
    Absorber: MB - Standard
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE12LP-H-MB-QED-D0

    Aperture: 9 x 9 mm
    Max. energy: 3.9 J
    Absorber: MB - Standard
    Attenuator: QED

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE12SP-S-MT-D0

    Aperture: 12 x 12 mm
    Max. energy: 0.70 J
    Absorber: MT - High Repetition Rate
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE12SP-H-MT-D0

    Aperture: 12 x 12 mm
    Max. energy: 0.70 J
    Absorber: MT - High Repetition Rate
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE12HR-H-MT-D0

    Aperture: 12 x 12 mm
    Max. energy: 0.70 J
    Absorber: MT - High repetition rate (tuned for short pulses)
    Attenu...

    Traceable calibration:

    Logo nist

    IS50A-1KW-RMT-D0

    Aperture: 50 mm Ø
    Max. energy: 1 J
    Absorber: Pyroelectric

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    PRONTO-250-FLEX

    Aperture: 19 mm Ø
    Max. power: 250 W
    Cooling: Convection
    Absorber: H - Broadband

    Traceable calibration:

    Logo nist

    QE145LP-S-MB-D0

    Aperture: 145 mm Ø
    Max. energy: 135 J
    Absorber: MB - Standard
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE145LP-H-MB-QED-D0

    Aperture: 135 mm Ø
    Max. energy: 385 J
    Absorber: MB - Standard
    Attenuator: QED

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE195LP-S-MB-D0

    Aperture: 195 mm Ø
    Max. energy: 250 J
    Absorber: MB - Standard
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE195LP-H-MB-QED-D0

    Aperture: 185 mm Ø
    Max. energy: 700 J
    Absorber: MB - Standard
    Attenuator: QED

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE25LP-S-MB-D0

    Aperture: 25 x 25 mm
    Max. energy: 3.8 J
    Absorber: MB - Standard
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE25LP-S-MB-QED-D0

    Aperture: 22 x 22 mm
    Max. energy: 23 J
    Absorber: MB - Standard
    Attenuator: QED

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE25LP-H-MB-D0

    Aperture: 25 x 25 mm
    Max. energy: 3.8 J
    Absorber: MB - Standard
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE25LP-H-MB-QED-D0

    Aperture: 22 x 22 mm
    Max. energy: 23 J
    Absorber: MB - Standard
    Attenuator: QED

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE25SP-S-MT-D0

    Aperture: 25 x 25 mm
    Max. energy: 3.0 J
    Absorber: MT - High Repetition Rate
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE25SP-H-MT-D0

    Aperture: 25 x 25 mm
    Max. energy: 3.0 J
    Absorber: MT - High Repetition Rate
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE25HR-H-MT-D0

    Aperture: 25 x 25 mm
    Max. energy: 3.0 J
    Absorber: MT - High repetition rate (tuned for short pulses)
    Attenua...

    Traceable calibration:

    Logo nist

    QE50LP-S-MB-D0

    Aperture: 50 x 50 mm
    Max. energy: 15 J
    Absorber: MB - Standard
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE50LP-S-MB-QED-D0

    Aperture: 47 x 47 mm
    Max. energy: 85 J
    Absorber: MB - Standard
    Attenuator: QED

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE50LP-H-MB-D0

    Aperture: 50 x 50 mm
    Max. energy: 15 J
    Absorber: MB - Standard
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE50LP-H-MB-QED-D0

    Aperture: 47 x 47 mm
    Max. energy: 85 J
    Absorber: MB - Standard
    Attenuator: QED

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE50SP-S-MT-D0

    Aperture: 50 x 50 mm
    Max. energy: 13 J
    Absorber: MT - High Repetition Rate
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE50SP-H-MT-D0

    Aperture: 50 x 50 mm
    Max. energy: 13 J
    Absorber: MT - High Repetition Rate
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE8SP-B-BL-D0

    Aperture: 7.8 x 7.8 mm
    Max. energy: 2.5 mJ
    Absorber: BL - Spectrally flat
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE8SP-B-MT-D0

    Aperture: 7.8 x 7.8 mm
    Max. energy: 0.93 mJ
    Absorber: MT - High Repetition Rate
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE12HR-H-MB-D0

    Aperture: 12 x 12 mm
    Max. energy: 0.85 J
    Absorber: MB - Standard (tuned for short pulses)
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE12HR-H-MB-QED-D0

    Aperture: 9 x 9 mm
    Max. energy: 3.9 J
    Absorber: MB - Standard (tuned for short pulses)
    Attenuator: QED

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE25HR-H-MB-D0

    Aperture: 25 x 25 mm
    Max. energy: 3.8 J
    Absorber: MB - Standard (tuned for short pulses)
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE25HR-H-MB-QED-D0

    Aperture: 22 x 22 mm
    Max. energy: 23 J
    Absorber: MB - Standard (tuned for short pulses)
    Attenuator: QED

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    PE10B-Si-D0

    Aperture: 10 mm Ø
    Max. energy: 81 nJ
    Absorber: UV-Silicon

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    PE5B-Ge-D0

    Aperture: 5 mm Ø
    Max. energy: 2.4 nJ
    Absorber: Germanium

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    PRONTO-500-IPL

    Aperture: 55 mm Ø
    Max. power:
    Cooling: Convection
    Absorber: H - Broadband

    Traceable calibration:

    Logo nist

    PE3B-Si-D0

    Aperture: 3 mm Ø
    Max. energy: 24 pJ
    Absorber: UV-Silicon

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    PE3B-In-D0

    Aperture: 3 mm Ø
    Max. energy: 245 pJ
    Absorber: InGaAs

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE95LP-S-MB-D0

    Aperture: 95 mm Ø
    Max. energy: 70 J
    Absorber: MB - Standard
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE95LP-S-MB-QED-D0

    Aperture: 90 mm Ø
    Max. energy: 250 J
    Absorber: MB - Standard
    Attenuator: QED

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE95LP-H-MB-D0

    Aperture: 95 mm Ø
    Max. energy: 70 J
    Absorber: MB - Standard
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE95LP-H-MB-QED-D0

    Aperture: 90 mm Ø
    Max. energy: 250 J
    Absorber: MB - Standard
    Attenuator: QED

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE95ELP-S-MB-D0

    Aperture: 95 mm Ø
    Max. energy: 70 J
    Absorber: MB - Standard (tuned for long pulses)
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE95ELP-H-MB-D0

    Aperture: 95 mm Ø
    Max. energy: 70 J
    Absorber: MB - Standard (tuned for long pulses)
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE65LP-S-MB-D0

    Aperture: 65 x 65 mm
    Max. energy: 50 J
    Absorber: MB - Standard
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE65LP-S-MB-QED-D0

    Aperture: 62 x 62 mm
    Max. energy: 200 J
    Absorber: MB - Standard
    Attenuator: QED

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE65LP-H-MB-D0

    Aperture: 65 x 65 mm
    Max. energy: 50 J
    Absorber: MB - Standard
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE65LP-H-MB-QED-D0

    Aperture: 62 x 62 mm
    Max. energy: 200 J
    Absorber: MB - Standard
    Attenuator: QED

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE65ELP-S-MB-D0

    Aperture: 65 x 65 mm
    Max. energy: 50 J
    Absorber: MB - Standard (tuned for long pulses)
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    QE65ELP-H-MB-D0

    Aperture: 65 x 65 mm
    Max. energy: 50 J
    Absorber: MB - Standard (tuned for long pulses)
    Attenuator: None

    Traceable calibration:

    Logo nist

    Available with

    Logo Integra

    M6-6-Si

    Aperture: 6 mm Ø
    Max. energy: 200 µJ
    Absorber: Silicon

    Traceable calibration:

    Logo nist

    M6-6-Si-L

    Aperture: 6 mm Ø
    Max. energy: 2 µJ
    Absorber: Silicon

    Traceable calibration:

    Logo nist

    M6-6-In

    Aperture: 6 mm Ø
    Max. energy: 200 µJ
    Absorber: InGaAs

    Traceable calibration:

    Logo nist

    M6-6-In-L

    Aperture: 6 mm Ø
    Max. energy: 2 µJ
    Absorber: InGaAs

    Traceable calibration:

    Logo nist

    M6-6-PY

    Aperture: 6 mm Ø
    Max. energy: 2 mJ
    Absorber: Pyroelectric

    Traceable calibration:

    Logo nist

    M6-12.5-PY

    Aperture: 12.5 mm Ø
    Max. energy: 20 mJ
    Absorber: Pyroelectric

    Traceable calibration:

    Logo nist

    QUAD-9-MT-E

    4-quadrant laser position sensing detector for pulsed lasers.

    QUAD-20-MT-E

    4-quadrant laser position sensing detector for pulsed lasers.

    SINGLE-SHOT ENERGY

    Most of our power detectors can also work in single-shot energy mode to measure the energy of a single pulse or of a tra...

    Traceable calibration:

    Logo nist

    Available with

    Logo blu Logo Integra

    QS2-H

    2 mm Ø, discrete pyroelectric sensor with metallic coating, high average power, in TO5 packaging.

    Traceable calibration:

    Logo nist

    QS3-H

    3 mm Ø, discrete pyroelectric sensor with metallic coating, high average power, in TO5 packaging.

    Traceable calibration:

    Logo nist

    QS5-H

    5 mm Ø, discrete pyroelectric sensor with metallic coating, high average power, in TO5 packaging.

    Traceable calibration:

    Logo nist

    QS9-H

    9 mm Ø, discrete pyroelectric sensor with metallic coating, high average power, in TO8 packaging.

    Traceable calibration:

    Logo nist

    PRODUCT FINDER

    Measurement type:

    1

    Beam size

    2

    Laser type

    3

    Beam profile

    Need help choosing?

    PRODUCT FINDER
    COPYRIGHT ©2024 Gentec-eo Spektrum média